Mount a Serax Glass Cabinet to Concrete With Hilti Anchors in 6 Steps
A Serax glass display cabinet loaded with stoneware can exceed 40 kg, and a back panel may give you only two or four fixing points. This revised sequence uses Hilti HUS3 screw anchors, an 8 mm masonry hole, and controlled torque to keep the cabinet tight to poured concrete.
Why poured concrete changes the fixing
Poured concrete around C20/25 takes a screw anchor through friction and mechanical interlock along the cut thread flanks. That load path differs from the way expansion sleeves work in hollow brick or plasterboard, where the fixing depends on a sleeve expanding or gripping inside a weaker cavity.
A Hilti HUS3-H 6 or HUS3-H 8 cuts its own thread into a pre-drilled bore. The load transfers straight into the concrete matrix, so there is no plastic plug in the wall to creep, compress, or crush during years of steady pull. With a Serax cabinet carrying glass shelves and stoneware, the critical action is the top edge trying to pull away as the cabinet rotates forward around its lower edge.
Hilti publishes recommended loads for the HUS3 range in its technical data. An 8 mm diameter anchor with 60 mm embedment in cracked C20/25 has published tension and shear values well above the share imposed by a 40 kg cabinet spread over four fixing points. That surplus is intentional. Edge distance, dust in the bore, and short embedment all reduce capacity, so the published value assumes the anchor was set as specified.
Mark the cabinet and prove the wall is concrete
Hold the cabinet at its final height and mark the fixing holes through the keyholes or bracket slots. Serax cabinets in the Studio Pieter Stockmans and Glass lines typically have two upper brackets that take most of the tensile load, with two lower points that mainly resist shear, so keep track of which marks belong to the upper and lower fixings.
Check the substrate before drilling all the holes. A solid concrete wall gives a dull, dead sound when tapped across the marked zone. A hollow ring suggests a stud cavity, rendered blockwork, or another build-up behind the finish.
A 6 mm test hole gives a clearer answer. Concrete produces fine grey dust and slow progress under the bit. A sudden drop in resistance means the drill has entered a void or passed through a softer render coat into something else. Where the render is more than 20 mm thick, the anchor embedment has to continue into the structural concrete behind it, because render by itself contributes almost nothing as anchorage.
Drill the right hole, then keep drilling depth consistent
Use a rotary hammer such as the Hilti TE 2-A22, or any SDS-plus drill fitted with a carbide masonry bit matched to the anchor diameter. For an HUS3-H 8, the hole is 8 mm. Enlarging it to 8.5 mm may make the screw easier to start, yet it reduces the thread contact that the anchor relies on.
Set the depth at least 10 mm beyond the intended embedment. The extra space gives loose cuttings somewhere to go, instead of compacting under the anchor tip. For 60 mm embedment, drill to about 70 mm.
A depth stop is the cleanest way to keep all four holes the same. A band of tape on the bit shank also works if it is checked between holes. Keep the drill square to the wall within a few degrees. An angled bore makes the screw anchor bend slightly as it seats, which cuts down the effective thread contact carrying the pull from the cabinet.
Clean each bore
Drilling dust left in the hole acts like a slip layer between the HUS3 thread and the concrete. It also keeps the thread flanks from biting into solid material.
Use a manual blow-out pump, then a stiff nylon or steel brush sized to the bore, then blow the hole again. Hilti setting instructions for screw anchors in dry concrete specify two blow, brush, blow cycles.
Set the anchor and bring it to torque
Drive each HUS3-H through the cabinet bracket into the cleaned hole with the correct hex head bit. An impact driver can run the screw in, and a torque wrench gives better control for the final seating.
The anchor cuts the concrete thread as it advances. Stop the rapid driving once the head or washer has pulled the bracket firmly against the back panel and the panel is seated against the wall. For the 8 mm size, Hilti data puts the recommended installation torque near 30 Nm.
If the driver keeps hammering after the head has seated, the freshly formed concrete thread can tear away. A damaged bore spins freely, carries no useful load, and forces the fixing to move to a fresh position with at least the required spacing from the failed hole.
A head that has not fully clamped the bracket leaves movement in the assembly. Under the weight of a loaded cabinet, that tiny gap can become visible at the top edge or allow the bracket to fret against the back panel.
Set the clutch conservatively if using an impact driver. The last part of the turn is easier to judge with a calibrated wrench, especially where the cabinet hardware is thin and the wall surface is uneven.
Hang, level, and check the back panel
If the cabinet uses keyhole brackets, lift it onto the upper anchors first, then place the lower fixings. Put a 600 mm spirit level across the top edge and down one side before the lower anchors are finally tightened. Glass cabinets reveal rack and twist quickly: doors start to fall open, or they bind against the frame.
Press along the back panel and look for daylight or flex between the cabinet and the wall. Poured concrete is seldom perfectly flat. A high spot at one corner can hold the cabinet away from the surface, so tightening the opposite anchor distorts the carcass.
Where the wall bows, a thin nylon packing shim behind the affected bracket fills the gap. The shim lets the bracket bear evenly and keeps the load from passing through a single hard contact point. When all four anchors have reached torque and the level reads true in both axes, the cabinet is structurally ready to load.
Load check for four anchors
Take a Serax glass cabinet that weighs 18 kg empty and reaches 42 kg after stoneware and glassware are added. Gravity acts at the centre of mass. For a wall cabinet, that point sits roughly 150 mm out from the wall face.
That offset creates a tipping moment. The two upper anchors take the tensile reaction, while the lower pair bears back into the wall.
In that example, each upper anchor sees only a few hundred newtons of pull-out force. The value is about an order of magnitude below the published HUS3-H 8 tension rating for C20/25 concrete at 60 mm embedment. The 42 kg dead weight also creates shear, divided across the four anchors, and that demand is modest in the same calculation.
The reserve in those numbers assumes the holes are the right diameter and depth, the bores are cleaned, and the installation torque is controlled. Hole cleaning and torque control are especially important because the anchor relies on the concrete thread it cuts during installation. A larger anchor cannot compensate for a dirty bore or a stripped thread in the original hole.
A symmetric load check does not show what happens when one glass shelf is overfilled on one side. That shift moves the centre of mass sideways and can load a single upper anchor harder than the four-point sketch suggests. The bracket geometry of the particular cabinet, measured before drilling, is what decides whether the two upper fixing points have enough spacing. A shelf loaded heavily to one side leaves the unresolved point at the top corner: how much pull is being handed to a single fixing?